Your browser doesn't support javascript.
loading
Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear
Safety and Health at Work ; : 364-370, 2017.
Artículo en Inglés | WPRIM | ID: wpr-17172
ABSTRACT

BACKGROUND:

Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method.

METHODS:

Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV 102).

RESULTS:

The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p 0.05).

CONCLUSION:

This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Oído / Dispositivos de Protección de los Oídos / Audición / Métodos / Ruido Tipo de estudio: Estudio pronóstico Límite: Humanos Idioma: Inglés Revista: Safety and Health at Work Año: 2017 Tipo del documento: Artículo