Fixation of Traumatic Sternal Fractures Using SternaLock Plating System
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 309-311, 2013.
Artículo en Inglés | WPRIM | ID: wpr-174756
ABSTRACT
A 43-year-old man experienced chest trauma due to a car accident. Compound sternal fractures with severe dislocation were seen on computed tomography of the chest. Using a SternaLock plating system with manual reduction, fixation of the sternal fracture was successfully performed. There were no complications related to the operation.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Esternón / Tórax / Luxaciones Articulares Idioma: Inglés Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Año: 2013 Tipo del documento: Artículo