Your browser doesn't support javascript.
loading
Intravascular Ultrasound Analysis of Factors Associated with Suboptimal Stent Expansion after High Pressure Balloon Inflation
Korean Circulation Journal ; : 1272-1279, 1997.
Artículo en Coreano | WPRIM | ID: wpr-180378
ABSTRACT

BACKGROUND:

The intracoronary stent implantation is regarded as an effective treatment modality of coronary artery disease. However, inadequate stent expansion was associated with subacute stent thrombosis and late restenosis. The high-pressure inflation stenting reduced the incidence of stent thrombosis and restenosis. Therefore, we intended to evaluate factors associated with suboptimal stent expansion after high-pressure balloon inflation.

METHODS:

One hundred and thirty eight patients with 150 lesions were treated with 168 stents of various types. Intravascular ultrasound(IVUS) images were obtained after angiographic optimization( or =90% of the distal reference lumen CSA. Severe calcifications were defined by IVUS as are of calcium > or =180 degree.

RESULTS:

An optimal stent expansion was achieved in 67% of the 150 lesions. At preintervention, severe calcifications were in 10%(5/51) in optimal stent expansion and in 40%(4/10)in suboptimal stent expansion(p<0.05). At postintervention, minimal stent CSA was 8.0mm2 in optimal stnet expansion and 6.5mm2 in suboptimal stent expansion(p<0.01). Minor diameter at stented segment was 2.9mm in optimal stent expansion and 2.5mm in suboptimal stent expansion(p<0.01). The symmetrical index of stent expansion(SI, a ratio of the minor diameter divided by the major diameter) was 0.91 in optimal stent expansion and 0.85 in suboptimal stent expansion(p<0.01). The residual plaque burden at stented segment was larger in suboptimal stent expansion than in optimal stent expansion(56% vs 51%, p<0.01).

CONCLUSIONS:

Severe calcifications at preintervention, larger residual plaque burden and smaller SI at postintervention may be related to suboptimal stent expansion, as assessed by IVUS, despite angiographic optimization with high-pressure inflation stenting.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Trombosis / Enfermedad de la Arteria Coronaria / Stents / Calcio / Incidencia / Ultrasonografía / Inflación Económica Tipo de estudio: Estudio diagnóstico / Estudio de incidencia / Estudio pronóstico Límite: Humanos Idioma: Coreano Revista: Korean Circulation Journal Año: 1997 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Trombosis / Enfermedad de la Arteria Coronaria / Stents / Calcio / Incidencia / Ultrasonografía / Inflación Económica Tipo de estudio: Estudio diagnóstico / Estudio de incidencia / Estudio pronóstico Límite: Humanos Idioma: Coreano Revista: Korean Circulation Journal Año: 1997 Tipo del documento: Artículo