Cervical Pedicle Screw Placement Using Medial Funnel Technique
Korean Journal of Spine
;
: 84-88, 2017.
Artículo
en Inglés
| WPRIM
| ID: wpr-187211
ABSTRACT
OBJECTIVE:
Cervical pedicle screw (CPS) placement is very challenging due to high risk of neurovascular complications. We devised a new technique (medial funnel technique) to improve the accuracy and feasibility of CPS placement.METHODS:
We reviewed 28 consecutive patients undergoing CPS instrumentation using the medial funnel technique. Their mean age was 51.4 years (range, 30–81 years). Preoperative diagnosis included degenerative disease (n=5), trauma (n=22), and infection (n=1). Screw perforations were graded with the following criteria grade 0 having no perforation, grade 1 having 50% of screw diameter. Grades 0 and 1 were considered as correct position. The degree of perforation was determined by 2 junior neurosurgeons and 1 senior neurosurgeon.RESULTS:
A total of 88 CPSs were inserted. The rate of correct placement was 94.3%; grade 0, 54 screws; grade 1, 29 screws; grade 2, 4 screws; and grade 3, 1 screw. No neurovascular complications or failure of instrumentation occurred. In perforated screws (34 screws), lateral perforations were 4 and medial perforations were 30.CONCLUSION:
We performed CPS insertion using medial funnel technique and achieved 94.3% (83 of 88) of correct placement. And it can decrease lateral perforation.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Tornillos Óseos
/
Vértebras Cervicales
/
Diagnóstico
/
Tornillos Pediculares
/
Neurocirujanos
Tipo de estudio:
Estudio diagnóstico
Límite:
Femenino
/
Humanos
Idioma:
Inglés
Revista:
Korean Journal of Spine
Año:
2017
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS