Your browser doesn't support javascript.
loading
Airway obstruction in heat & moisture exchanger filter: A case report
Anesthesia and Pain Medicine ; : 96-99, 2011.
Artículo en Inglés | WPRIM | ID: wpr-192482
ABSTRACT
Heat and moisture exchanger filters (HMEF), used for humidification of patient respiratory gas and filtering microorganisms can cause airway obstruction. We experienced serious airway obstruction in a HMEF after making hydrothorax for high intensity focused ultrasound (HIFU) procedure. The airway obstruction was difficult to differentiate from severe bronchospasm irresponsive to bronchodilator therapy. It was relieved dramatically after we removed the filter from the breathing circuit as soon as we detected air-fluid meniscus in it.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Respiración / Espasmo Bronquial / Obstrucción de las Vías Aéreas / Calor / Hidrotórax Límite: Humanos Idioma: Inglés Revista: Anesthesia and Pain Medicine Año: 2011 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS