Your browser doesn't support javascript.
loading
Removal of Kirschner Wire Migrated into the Video Assisted Thoracic Cavity by Thoracoscopic Surgery / 대한흉부외과학회지
Article en Ko | WPRIM | ID: wpr-192512
Biblioteca responsable: WPRO
ABSTRACT
Metallic fixations devices are widely used in the surgical management of fractures and dislocations of shoulder. It is known that Kirschner wire (K-wire) may migrate into the thoracic cavity or other organs may occur. We report a case in which a K-wire previously placed in the clavicle migrated into the thoracic cavity without causing any trauma to the major vascular structures and was removed successfully by thoracoscopic surgery.
Asunto(s)
Palabras clave
Texto completo: 1 Índice: WPRIM Asunto principal: Hombro / Toracoscopía / Migración de Cuerpo Extraño / Clavícula / Cavidad Torácica / Luxaciones Articulares Idioma: Ko Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Año: 2006 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Asunto principal: Hombro / Toracoscopía / Migración de Cuerpo Extraño / Clavícula / Cavidad Torácica / Luxaciones Articulares Idioma: Ko Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Año: 2006 Tipo del documento: Article