Your browser doesn't support javascript.
loading
Lung Ultrasound (in the Critically Ill) Superior to CT: the Example of Lung Sliding / 대한중환자의학회지
Korean Journal of Critical Care Medicine ; : 1-8, 2017.
Artículo en Inglés | WPRIM | ID: wpr-194706
ABSTRACT
This review article shows the potential of lung ultrasound in the critically ill (LUCI) to study lung sliding and describes the optimal equipment for its assessment. Then, it analyses the integration of lung sliding within lung ultrasound then whole body critical ultrasound. It describes the place of lung sliding in the BLUE-protocol (bedside lung ultrasound in emergency) (lung and venous ultrasound for diagnosing acute respiratory failure), the FALLS-protocol (fluid administration limited by lung sonography) (the role of lung sliding in circulatory failure), and the SESAME-protocol (sequential assessment of sonography assessing mechanism or origin of severe shock of indistinct cause) (whole body ultrasound in cardiac arrest). In the LUCIFLR project (LUCI favoring limitation of radiations), the consideration of lung sliding allows drastic reduction in irradiation and costs. In conclusion, lung sliding is proposed as a gold standard for indicating the presence of the lung at the chest wall and its correct expansion.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Neumotórax / Choque / Ultrasonografía / Enfermedad Crítica / Pared Torácica / Pulmón Tipo de estudio: Estudio diagnóstico / Guía de Práctica Clínica Idioma: Inglés Revista: Korean Journal of Critical Care Medicine Año: 2017 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Neumotórax / Choque / Ultrasonografía / Enfermedad Crítica / Pared Torácica / Pulmón Tipo de estudio: Estudio diagnóstico / Guía de Práctica Clínica Idioma: Inglés Revista: Korean Journal of Critical Care Medicine Año: 2017 Tipo del documento: Artículo