Your browser doesn't support javascript.
loading
Laparoscopic Removal of a Vertebral Foreign Body / 대한내시경복강경외과학회지
Article en Ko | WPRIM | ID: wpr-195608
Biblioteca responsable: WPRO
ABSTRACT
We report a case of laparoscopic removal of a retained foreign body, a broken surgical instrument, after posterior lumbar decompression and interbody fusion (PLIF) for infection control of the vertebrae. The surgical instrument was broken during PLIF surgery. However, the orthopedic surgeon could not remove the broken instrument because of bleeding and a poor operative view; the surgeon finished the operation leaving the broken surgical instrument in the vertebral body. Plain films revealed a metallic pin-like material at the anterior side of the lumbar vertebral body. Six days later, through a laparoscopic approach, the broken surgical instrument was removed without complication, and the orthopedic surgeon completed the planned operation successfully.
Asunto(s)
Palabras clave
Texto completo: 1 Índice: WPRIM Asunto principal: Ortopedia / Columna Vertebral / Instrumentos Quirúrgicos / Control de Infecciones / Laparoscopía / Descompresión / Cuerpos Extraños / Hemorragia Idioma: Ko Revista: Journal of the Korean Society of Endoscopic & Laparoscopic Surgeons Año: 2009 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Asunto principal: Ortopedia / Columna Vertebral / Instrumentos Quirúrgicos / Control de Infecciones / Laparoscopía / Descompresión / Cuerpos Extraños / Hemorragia Idioma: Ko Revista: Journal of the Korean Society of Endoscopic & Laparoscopic Surgeons Año: 2009 Tipo del documento: Article