The Use of Contrast in Caudal Epidural Injections under Image Intensifier Guidance: Is It Necessary?
Clinics in Orthopedic Surgery
;
: 190-192, 2017.
Artículo
en Inglés
| WPRIM
| ID: wpr-202490
ABSTRACT
BACKGROUND:
We investigated the value of using contrast as an additional aid to confirm the accuracy of needle placement for caudal epidural injections under intraoperative image intensifier guidance.METHODS:
A total of 252 consecutive patients were included in this study. Their mean age was 46.7 years (range, 32 to 76 years). There were 133 males (53%) and 119 females (47%) over a 12-month period.RESULTS:
Of the 252 consecutive procedures, the contrast enhanced image intensifier confirmed accurate needle placement on first attempt in 252 cases (100%). Needle resiting following the infiltration of contrast was required in 0 case.CONCLUSIONS:
The results from this study demonstrate that a surgeon beyond the learning curve can accurately place caudal epidural injections using image intensification only, without the use of contrast.