The Use of Contrast in Caudal Epidural Injections under Image Intensifier Guidance: Is It Necessary?
Clinics in Orthopedic Surgery ; : 190-192, 2017.
Artículo en Inglés | WPRIM | ID: wpr-202490
ABSTRACT

BACKGROUND:

We investigated the value of using contrast as an additional aid to confirm the accuracy of needle placement for caudal epidural injections under intraoperative image intensifier guidance.

METHODS:

A total of 252 consecutive patients were included in this study. Their mean age was 46.7 years (range, 32 to 76 years). There were 133 males (53%) and 119 females (47%) over a 12-month period.

RESULTS:

Of the 252 consecutive procedures, the contrast enhanced image intensifier confirmed accurate needle placement on first attempt in 252 cases (100%). Needle resiting following the infiltration of contrast was required in 0 case.

CONCLUSIONS:

The results from this study demonstrate that a surgeon beyond the learning curve can accurately place caudal epidural injections using image intensification only, without the use of contrast.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Columna Vertebral / Inyecciones Epidurales / Fluoroscopía / Curva de Aprendizaje / Anestesia Caudal / Agujas Tipo de estudio: Guía de Práctica Clínica Límite: Femenino / Humanos / Masculino Idioma: Inglés Revista: Clinics in Orthopedic Surgery Año: 2017 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Columna Vertebral / Inyecciones Epidurales / Fluoroscopía / Curva de Aprendizaje / Anestesia Caudal / Agujas Tipo de estudio: Guía de Práctica Clínica Límite: Femenino / Humanos / Masculino Idioma: Inglés Revista: Clinics in Orthopedic Surgery Año: 2017 Tipo del documento: Artículo