The Usefulness of Thin-Section Spiral CT in the Evaluation of Mediastinal Lymph Node Metastasis from Non-Small Cell Lung Cancer: AProspective Study and Comparison with Thick-Section Spiral CT
Journal of the Korean Radiological Society
;
: 765-770, 2000.
Artículo
en Coreano
| WPRIM
| ID: wpr-202523
ABSTRACT
PURPOSE:
To compare the accuracy of thick-and thin-section spiral CT and to determine whether, in diagnosing mediastinal lymph node metastasis from non-small cell lung cancer, the latter is superior to the former. MATERIALS ANDMETHODS:
Between March 1997 and March 1998, 51 patients with pathologically proven non-s-mall cell lung cancer underwent thoracotomy with full nodal dissection. Thick- and thin-section spiral CT were performed in all patients, with a mean interval of 14 days. The former was performed with 10 mm thick-ness and 10 mm interval, and the latter with 3 mm thickness and 3 mm interval. Mediastinal lymph nodes were localized according to the lymph node mapping scheme of the American Thoracic Society and were considered positive for metastasis if they exceeded 10 mm in short-axis diameter.RESULTS:
A total of 227 mediastinal nodal stations in 51 patients were obtained. Of these, 188 stations included in thin-section spiral CT were analyzed and the prevalence of ediastinal nodal metastasis was found to be 10%. On a station-by-station basis, and for thick-and thin-section spiral CT, respectively, the overall sensitivi-ties of mediastinal lymph node metastasis were 32% and 53% (p .05). Although there were no statistically significant differences in sensitivity and specificity according to nodal station, thin-section spiral CT tended to be superior to the thick-section type for stations 7 and 10R in terms of sensitivity, and for stations 4L and 5 in terms of specificity.CONCLUSION:
Thin-section spiral CT was more sensitive than thick-section spiral CT is the evaluation of medi-astinal lymph node metastasis from non-small cell lung cancer. This may be due to the higher resolution of the former and its ability to discriminate between lymph node and vessel.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Toracotomía
/
Prevalencia
/
Sensibilidad y Especificidad
/
Carcinoma de Pulmón de Células no Pequeñas
/
Tomografía Computarizada Espiral
/
Neoplasias Pulmonares
/
Ganglios Linfáticos
/
Metástasis de la Neoplasia
Tipo de estudio:
Estudio diagnóstico
/
Estudio de prevalencia
Límite:
Humanos
Idioma:
Coreano
Revista:
Journal of the Korean Radiological Society
Año:
2000
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS