ABSTRACT
We present a case report of a 45-year-old woman with spontaneous pneumocephalus accompanied by pneumorrhachis of the thoracic spine, which is a very rare condition generally associated with trauma and thoracic or spinal surgery. The patient had undergone an operation about 10 years earlier to treat a giant cell tumor of the thoracic spine. During the operation, a metallic device was installed, which destroyed the bronchus and caused the formation of a broncho-paraspinal fistula. This is the suspected cause of her pneumocephalus and pneumorrhachis. To our knowledge, this is a very rare case of pneumocephalus accompanied by pneumorrhachis induced by metallic device, and when considering the length of time after surgery these complications presented are also exceptional.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Neumocéfalo / Columna Vertebral / Bronquios / Neumorraquis / Fístula / Tumores de Células Gigantes Límite: Femenino / Humanos Idioma: Inglés Revista: Journal of Korean Neurosurgical Society Año: 2011 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Neumocéfalo / Columna Vertebral / Bronquios / Neumorraquis / Fístula / Tumores de Células Gigantes Límite: Femenino / Humanos Idioma: Inglés Revista: Journal of Korean Neurosurgical Society Año: 2011 Tipo del documento: Artículo