Transarterial Embolization of a Carotid Cavernous Fistula with Guglielmi Detachable Coils: A Case Report
Journal of the Korean Radiological Society ; : 585-587, 1998.
Artículo en Coreano | WPRIM | ID: wpr-211642
ABSTRACT
In the management of carotid cavernous fistula, detachable balloon has become the treatment of choice.However, technical difficulties are not uncommon, and transarterial balloon embolization fail in 5% to 10% ofcases. Failure occurs because in some patients, the fistula orifice may be too small to allow entry. Using atracker catheter system with Guglielmi detachable coils, we achieved successful transarterial occlusion of acarotid cavernous fistula with a small fistula.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Oclusión con Balón / Catéteres / Fístula Límite: Humanos Idioma: Coreano Revista: Journal of the Korean Radiological Society Año: 1998 Tipo del documento: Artículo