Your browser doesn't support javascript.
loading
Reproducibilities of cephalometric measurements of three-dimensional CT images reconstructed in the personal computer / 대한구강악안면방사선학회지
Korean Journal of Oral and Maxillofacial Radiology ; : 171-178, 2003.
Artículo en Coreano | WPRIM | ID: wpr-221763
ABSTRACT

PURPOSE:

The purpose of this study was to report the reproducibility of intra-observer and inter-observer consistency of cephalometric measurements using three-dimensional (3D) computed tomography (CT), and the degree of difference of the cephalometric measurements. MATERIALS AND

METHODS:

CT images of 16 adult patients with normal class I occlusion were sent to personal computer and reconstructed into 3D images using V-Works 3.5 TM (Cybermed Inc., Seoul, Korea). With the internal program of V-Works 3.5 TM, 12 landmarks on regular cephalograms were transformed into 21 analytic categories and measured by 2 observers and in addition, one of the observers repeated their measurements. Intra-observer difference was calculated using paired t-test, and inter-observer by two sample test.

RESULTS:

There were significant differences in the intra-observer measurements (p< 0.05) in four of the categories which included ANS-Me, ANS-PNS, Cdl-Go (Lt), GoL-GoR, but with the exception of Cdl-Go (Lt), ZmL-ZmR, Zyo-Zyo, the average differences were within 2 mm of each other. The inter-observer observations also showed significant differences in the measurements of the ZmL-ZmR and Zyo-Zyo categories (p< 0.05). With the exception of the Cdl-Me (Rt), ZmL-ZmR, Zyo-Zyo categories, the average differences between the two observers were within 2 mm, but the ZmL-ZmR and Zyo-Zyo values differed greatly with values of 8.10 and 19.8 mm respectively.

CONCLUSION:

In general, 3D CT images showed greater accuracy and reproducibility, with the exception of suture areas such as Zm and Zyo, than regular cephalograms in orthodontic measurements, showing differences of less than 2 mm, therefore 3D CT images can be useful in cephalometric measurements and treatment planning.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Suturas / Microcomputadores / Tomografía Computarizada por Rayos X / Cefalometría / Reproducibilidad de los Resultados / Seúl Límite: Adulto / Humanos País/Región como asunto: Asia Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Año: 2003 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Suturas / Microcomputadores / Tomografía Computarizada por Rayos X / Cefalometría / Reproducibilidad de los Resultados / Seúl Límite: Adulto / Humanos País/Región como asunto: Asia Idioma: Coreano Revista: Korean Journal of Oral and Maxillofacial Radiology Año: 2003 Tipo del documento: Artículo