Surgical Results of Transscleral Fixation of Foldable Acrylic Intraocular lens with Unique Shape of Haptics
Journal of the Korean Ophthalmological Society
;
: 1071-1077, 2008.
Artículo
en Coreano
| WPRIM
| ID: wpr-225349
ABSTRACT
PURPOSE:
To report the surgical results of transscleral fixation of foldable acrylic intraocular lens with a unique haptic shape (CORNEAL(R), ACR6D, France).METHODS:
We analyzed the medical records of 18 patients (19 eyes) who had transscleral fixation of posterior chamber intraocular lens implantation from July 2004 to July 2006.RESULTS:
According to the cause of operation, there were five eyes with complicated cataract, eight with trauma, and six with aphakia associated with a previous operation. The mean age of the patients was 55.9+/-21.2 years. The mean preoperative best-corrected visual acuity was 0.31+/-0.35, and the postoperative value was 0.63+/-0.29 (p<0.05). The mean preoperative spherical refractive equivalent was 6.58+/-5.33 diopter, and the postoperative value was -1.77+/-1.59 diopter. The mean refractive error was -1.13+/-1.57 diopter. This showed a myopic shift (p<0.05). The mean astigmatism decreased with time, and it stabilized two months after the operation. The trend was toward mild against-the-rule astigmatism. The mean follow-up duration was 11.0+/-7.6 months.CONCLUSIONS:
In eyes with inadequate capsular support, transscleral fixation of posterior chamber intraocular lens implantation with CORNEAL(R) lenses is a safe and effective procedure for visual correction.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Afaquia
/
Errores de Refracción
/
Astigmatismo
/
Catarata
/
Agudeza Visual
/
Registros Médicos
/
Estudios de Seguimiento
/
Implantación de Lentes Intraoculares
/
Ojo
/
Lentes Intraoculares
Tipo de estudio:
Estudio observacional
/
Estudio pronóstico
Límite:
Humanos
Idioma:
Coreano
Revista:
Journal of the Korean Ophthalmological Society
Año:
2008
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS