Your browser doesn't support javascript.
loading
Redoing a bioprosthetic tricuspid valve replacement with pacemaker wire through the ruined bioprosthetic valve orifice / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 958-960, 2011.
Artículo en Inglés | WPRIM | ID: wpr-239914
ABSTRACT
Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient.
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Marcapaso Artificial / Cirugía General / Válvula Tricúspide Límite: Adulto / Femenino / Humanos Idioma: Inglés Revista: Chinese Medical Journal Año: 2011 Tipo del documento: Artículo

Similares