Performance of internal-loop air-lift nitrifying bioreactor / 生物工程学报
Chinese Journal of Biotechnology
;
(12): 492-496, 2002.
Artículo
en Chino
| WPRIM
| ID: wpr-256178
ABSTRACT
The performance of internal-loop air-lift nitrifying bioreactor was good with strong tolerance to influent ammonia concentration (78.49 mmol/L), high volume converting rate (163.18 mmol/L.d) and obvious working stability (ammonia removal > 94.42%). During operation of internal-loop air-lift bioreactor, the nitrifying activated sludge was granulated. The nitrifying granular activated sludge began to appear on day 45. Its average diameter was 0.83 mm, settling velocity was 55.53 m/h and specific ammonia removal rate was 0.95 mmol (NH4(+)-N)/g (VS).d. The nitrifying granular activated sludge had the activity for anaerobic ammonia oxidation with ammonia oxidation rate of 0.23 mmol (NH4(+)-N)/g(VS).d and nitrite reduction rate of 0.24 mmol (NO2(-)-N)/g(VS).d.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Oxidación-Reducción
/
Aguas del Alcantarillado
/
Reactores Biológicos
/
Amoníaco
/
Anaerobiosis
/
Metabolismo
/
Nitritos
/
Nitrógeno
Idioma:
Chino
Revista:
Chinese Journal of Biotechnology
Año:
2002
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS