Your browser doesn't support javascript.
loading
Visual detection of murray valley encephalitis virus by reverse transcription loop-mediated isothermal amplification / 生物医学与环境科学(英文)
Biomedical and Environmental Sciences ; (12): 227-230, 2015.
Artículo en Inglés | WPRIM | ID: wpr-264595
ABSTRACT
A sensitive reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for rapid visual detection of Murray valley encephalitis virus (MVEV) infection. The reaction was performed in one step in a single tube at 63 °C for 60 min with the addition of the hydroxynaphthol blue (HNB) dye prior to amplification. The detection limit of the RT-LAMP assay was 100 copies per reaction based on 10-fold dilutions of in vitro transcribed RNA derived from a synthetic MVEV DNA template. No cross-reaction was observed with other encephalitis-associated viruses. The assay was further evaluated using spiked cerebrospinal fluid sample with pseudotype virus containing the NS5 gene of MVEV.
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Transcripción Genética / Secuencia de Bases / Virus de la Encefalitis del Valle Murray / Cartilla de ADN / Límite de Detección / Genética Tipo de estudio: Estudio diagnóstico Idioma: Inglés Revista: Biomedical and Environmental Sciences Año: 2015 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Transcripción Genética / Secuencia de Bases / Virus de la Encefalitis del Valle Murray / Cartilla de ADN / Límite de Detección / Genética Tipo de estudio: Estudio diagnóstico Idioma: Inglés Revista: Biomedical and Environmental Sciences Año: 2015 Tipo del documento: Artículo