Lethal coronary air embolism caused by the removal of a double-lumen hemodialysis catheter: a case report / 대한마취과학회지
Korean Journal of Anesthesiology
;
: 296-300, 2016.
Artículo
en Inglés
| WPRIM
| ID: wpr-26719
ABSTRACT
Coronary air embolism is a rare event. We report a case in which an acute myocardial infarction occurred in the region supplied by the right coronary artery after the removal of a double-lumen hemodialysis catheter. Emergent coronary angiography revealed air bubbles obstructing the mid-segment of the right coronary artery with slow flow phenomenon distally. The patient expired due to myocardial infarction.