Your browser doesn't support javascript.
loading
Percutaneous balloon pulmonary valvuloplasty for critical pulmonary stenosis in infants under 6 months of age and short and medium term follow-up / 中华儿科杂志
Chinese Journal of Pediatrics ; (12): 17-20, 2011.
Artículo en Chino | WPRIM | ID: wpr-286149
ABSTRACT
<p><b>OBJECTIVE</b>To evaluate the effect and results of short and medium periods of follow-up of percutaneous balloon pulmonary valvuloplasty for critical pulmonary stenosis of neonates and infants under 6 months of age.</p><p><b>METHODS</b>Between January 2002 and December 2008, 34 consecutive patients aged from 13 to 175 days with critical pulmonary valvular stenosis underwent percutaneous balloon valvuloplasty. Patients records, catheterization data, angiograms and echocardiograms were reviewed. Patients were followed up for 6 months to 4 years (mean 25.5 months) by means of clinical examination and Doppler echocardiography.</p><p><b>RESULTS</b>The pulmonary valvuloplasty was accomplished in 32 (94%) of 34 attempts. Immediately after dilation, right ventricular systolic pressure (RVSP) decreased from (96 ± 28) mm Hg (1 mm Hg = 0.133 kPa) (49 ± 20) mm Hg (P < 0.01), the transvalvular peak to peak systolic gradient (&Delta;P) decreased from (89 ± 25) mm Hg to (25 ± 12) mm Hg (P < 0.01), and the right ventricular/aortic systolic pressure ratio decreased from 1.2 ± 0.5 to 0.7 ± 0.3 (P < 0.01). One patient died because of cardiac tamponade following rupture of the pulmonary valve annulus, 2 patients developed pericardial effusion, 3 patients had infundibular spasm, 3 patients had a pre-dilation by small balloon and 1 patient had weakened femoral artery pollex. After a follow up period of 6 months to 4 years 3 of 31 patients lost to follow-up. Repeat valvuloplasty was performed in 5 patients (3 neonates), no patient required surgery, and the other 23 patients did not undergo further intervention, a mean peak systolic Doppler gradient of (20 ± 13) mm Hg was found and no significant pulmonary regurgitation was seen.</p><p><b>CONCLUSIONS</b>Percutaneous balloon pulmonary valvuloplasty was effective and safe for the treatment of critical pulmonary stenosis of neonates and infants under 6 months of age with good short and medium term results.</p>
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Válvula Pulmonar / Estenosis de la Válvula Pulmonar / Terapéutica / Cateterismo / Estudios de Seguimiento / Resultado del Tratamiento / Perdida de Seguimiento Tipo de estudio: Estudio observacional / Estudio pronóstico Límite: Femenino / Humanos / Lactante / Masculino / Recién Nacido Idioma: Chino Revista: Chinese Journal of Pediatrics Año: 2011 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Válvula Pulmonar / Estenosis de la Válvula Pulmonar / Terapéutica / Cateterismo / Estudios de Seguimiento / Resultado del Tratamiento / Perdida de Seguimiento Tipo de estudio: Estudio observacional / Estudio pronóstico Límite: Femenino / Humanos / Lactante / Masculino / Recién Nacido Idioma: Chino Revista: Chinese Journal of Pediatrics Año: 2011 Tipo del documento: Artículo