Your browser doesn't support javascript.
loading
Comparison of the flaps made by femtosecond laser and automated keratomes for sub-bowman keratomileusis / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 2440-2444, 2013.
Article en En | WPRIM | ID: wpr-322181
Biblioteca responsable: WPRO
ABSTRACT
<p><b>BACKGROUND</b>Thin-flap laser in situ keratomileusis (LASIK) is the new trend of refractive error correction surgery, the formation of corneal flap is crucial for a success of LASIK surgery. This study aimed to assess and compare the variations of LASIK flap created by the IntraLase femtosecond laser, Moria One Use-Plus SBK and Moria M2 Single-Use 90 µm-head microkeratome using Anterior segment optical coherence tomography (Visante OCT).</p><p><b>METHODS</b>One hundred and sixty-one eyes of 81 consecutive patients were enrolled in this prospective study and randomly divided into three groups depending on the flap creation method: flap creation with the the IntraLase femtosecond laser (IntraLase group, 59 eyes), flap creation with the Moria One Use-Plus SBK (SBK group, 44 eyes), and flap creation with the Moria M2 Single-Use 90 µm-head microkeratome (M2SU90 group, 58 eyes). The nominal flap thickness was 110 µm for all patients and for the three devices. One month after surgery, Visante OCT was used to measure the flap thickness at 20 locations on each cornea and the results were assessed for uniformity, regularity, and accuracy.</p><p><b>RESULTS</b>At 1 month after surgery, the mean central flap thickness was (111 ± 3) µm in the IntraLase group, (114 ± 8) µm in the SBK group, and (118 ± 13) µm in the M2SU90 group respectively. The flaps in the IntraLase group and the SBK group were more regular, showing an almost planar configuration, than the meniscus-shaped flaps in the M2SU90 group. The maximum deviation from the intended flap thickness (110 µm) was 6 µm in the IntraLase group, 10 µm in the SBK group, and 20 µm in the M2SU90 group respectively. A difference greater than 20 µm was observed in 0.42% of measurements in the IntraLase group; 2.95% of the measurements in the SBK group and 21.12% of measurements in the M2SU90 group.</p><p><b>CONCLUSIONS</b>The flaps created by the IntraLase femtosecond laser and Moria One Use-Plus SBK are more uniform; more regular, and more accurate than those created by the Moria M2 Single-Use 90 µm-head microkeratome. The first two methods can make precise flaps for Sub-Bowman Keratomileusis.</p>
Asunto(s)
Texto completo: 1 Índice: WPRIM Asunto principal: Colgajos Quirúrgicos / Queratomileusis por Láser In Situ / Tomografía de Coherencia Óptica / Métodos Tipo de estudio: Observational_studies Límite: Adolescent / Adult / Humans Idioma: En Revista: Chinese Medical Journal Año: 2013 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Asunto principal: Colgajos Quirúrgicos / Queratomileusis por Láser In Situ / Tomografía de Coherencia Óptica / Métodos Tipo de estudio: Observational_studies Límite: Adolescent / Adult / Humans Idioma: En Revista: Chinese Medical Journal Año: 2013 Tipo del documento: Article