Your browser doesn't support javascript.
loading
Simultaneous determination of water-soluble components and nerolidol in xiangdan injection by high performance liquid chromatography with column switching / 中国中药杂志
China Journal of Chinese Materia Medica ; (24): 2776-2780, 2008.
Artículo en Chino | WPRIM | ID: wpr-324808
ABSTRACT
<p><b>OBJECTIVE</b>Integrating column switching for on-line concentration and programmed injection, a novel HPLC method is developed for simultaneous determination of high-content water-soluble components (danshensu, protocatechualdehyde, salvianolic acid B) and trace nerolidol in Xiangdan injection. The concentrations of water-soluble components in Xiangdan injection are roughly 1000 times of that of nerolidol.</p><p><b>METHOD</b>The on-line concentration was performed on a Zorbax SB-C18 guard column. The separation was carried out on Lichrospher C18 column (4.6 mm x 250 mm, 5 microm). The mobile phase of guard column was mixtures of acetonitrile and 1.0% acetic acid water, and the flow rate was 0.5 mL x min(-1). The mobile phase of the analytical column was mixtures of acetonitrile and 0.05% acetic acid water, and the flow rate was set at 1.0 mL x min(-1). The column temperature was maintained at 40 degrees C, and the detection wavelength was 280 nm at 0-40 min, 210 nm at 40-55 min. The program injection was 10 microL of sample solution 1 at 0 min, 200 microL of sample solution 2 at 15.3 min.</p><p><b>RESULT</b>The calibration curves of danshensu, protocatechualdehyde, salvianolic acid B and nerolidol showed good linear regression (R2 > 0.9990) within investigated concentration ranges. The average recoveries of the four analytes were between l00% and 102%, and the RSD values were less than 3.0%. For danshensu, protocatechualdehyde, salvianolic acid B and nerolidol, the limits of detection at a signal-to-noise (S/N) ratio of 3 were 17.1, 0.473, 60.2, 50.6 microg x L(-1), respectively.</p><p><b>CONCLUSION</b>The method is a simple, sensitive and repeatable approach. More importantly, results indicate that the present method shows promising prospect for quality control of Xiangdan injection.</p>
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Sesquiterpenos / Solubilidad / Medicamentos Herbarios Chinos / Química / Cromatografía Líquida de Alta Presión / Métodos Idioma: Chino Revista: China Journal of Chinese Materia Medica Año: 2008 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Sesquiterpenos / Solubilidad / Medicamentos Herbarios Chinos / Química / Cromatografía Líquida de Alta Presión / Métodos Idioma: Chino Revista: China Journal of Chinese Materia Medica Año: 2008 Tipo del documento: Artículo