Correction of cupped ear by using a stainless steel wire suspension technique / 中华整形外科杂志
Chinese Journal of Plastic Surgery
;
(6): 288-289, 2004.
Artículo
en Chino
| WPRIM
| ID: wpr-327251
ABSTRACT
<p><b>OBJECTIVE</b>To evaluate a new reliable surgical technique for correction the congenital cupped ear.</p><p><b>METHODS</b>With 96 patients, a stainless steel wire was introduced to suspend auricular cartilage on the pericranium after the cupped ear was corrected. The follow-ups were carried out after the operation.</p><p><b>RESULTS</b>Up to 3 years follow-ups with 52 cases, the results were satisfactory and durable.</p><p><b>CONCLUSIONS</b>The above mentioned technique could be a reliable way to correct mild and moderate cupped ear abnormalities.</p>
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Alambres para Ortodoncia
/
Acero
/
Cirugía General
/
Anomalías Congénitas
/
Estudios de Seguimiento
/
Resultado del Tratamiento
/
Procedimientos de Cirugía Plástica
/
Oído
/
Métodos
Tipo de estudio:
Estudio observacional
/
Estudio pronóstico
Límite:
Adolescente
/
Adulto
/
Niño
/
Femenino
/
Humanos
/
Masculino
Idioma:
Chino
Revista:
Chinese Journal of Plastic Surgery
Año:
2004
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS