Your browser doesn't support javascript.
loading
Comparison Study of Left Ventricular Function Assessment by 18F-FDG PET, Gated SPECT and 2D-Echocardiography in Patients with Myocardial Infarction / 生物医学工程学杂志
Journal of Biomedical Engineering ; (6): 1090-1095, 2015.
Artículo en Chino | WPRIM | ID: wpr-357914
ABSTRACT
The aim of this study is to analyze the concordance between EDV, ESV and LVEF values derived from 18F-FDG PET, GSPECT and ECHO in patients with myocardial infarction. Sixty-four patients with coronary artery disease (CAD) and myocardial infarction were enrolled in the study. Each patient underwent at least two of the above mentioned studies within 2 weeks. LVEF, EDV and ESV values were analyzed with dedicated software. Statistical evaluation of correlation and agreement was carried out EDV was overestimated by 18F-FDG PET compared with GSPECT [(137.98 ± 61.71) mL and (125.35 ± 59.34) mL]; ESV was overestimated by 18F-FDG PET (85.89 ± 55.21) mL and GSPECT (82.39 ± 55.56) mL compared with ECHO (68.22 ± 41.37) mL; EF was overestimated by 18F-FDG PET (41.96% ± 15.08%) and ECHO (52.18% ± 13.87%) compared with GSPECT (39.75% ± 15.64%), and EF was also overestimated by 18F-FDG PET compared with GSPECT. The results of linear regression analysis showed good correlation between EDV, ESV and LVEF values derived from 18F-FDG PET, GSPECT and ECHO (r = 0.643-0.873, P = 0.000). Bland-Altman analysis indicated that 18F-FDG PET correlated well with ECHO in the Left ventricular function parameters. While GSPECT correlated well with 18F-FDG PET in ESV, GSPECT had good correlation with Echo in respect of EDV and EF; whereas GSPECT had poor correlation with PET/ECHO in the remaining left ventricular function parameters. Therefore, the clinical physicians should decide whether they would use the method according to the patients' situation and diagnostic requirements.
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Volumen Sistólico / Enfermedad de la Arteria Coronaria / Ecocardiografía / Modelos Lineales / Tomografía Computarizada de Emisión de Fotón Único / Análisis de Regresión / Función Ventricular Izquierda / Fluorodesoxiglucosa F18 / Tomografía de Emisión de Positrones / Diagnóstico Tipo de estudio: Estudio diagnóstico Límite: Humanos Idioma: Chino Revista: Journal of Biomedical Engineering Año: 2015 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Volumen Sistólico / Enfermedad de la Arteria Coronaria / Ecocardiografía / Modelos Lineales / Tomografía Computarizada de Emisión de Fotón Único / Análisis de Regresión / Función Ventricular Izquierda / Fluorodesoxiglucosa F18 / Tomografía de Emisión de Positrones / Diagnóstico Tipo de estudio: Estudio diagnóstico Límite: Humanos Idioma: Chino Revista: Journal of Biomedical Engineering Año: 2015 Tipo del documento: Artículo