Your browser doesn't support javascript.
loading
Analysis of Cut-off Value in Screening of Thalassemia by Capillary Hemoglobin Electrophoresis for Pregnant Women from Shenzhen Region of China / 中国实验血液学杂志
Journal of Experimental Hematology ; (6): 536-539, 2016.
Artículo en Chino | WPRIM | ID: wpr-360052
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the cut-off value in screening of thalassemia in pregnant women from Shenzhen region by capillary hemoglobin electrophoresis.</p><p><b>METHODS</b>The data of capillary hemoglobin electrophoresis and genetic diagnosis of thalassemia from 2122 examined prenatal women were retrospectively analyzed. Capillary hemoglobin electrophoresis and α-, β- genetic diagnosis of thalassemia were carried out for every woman. Hemoglobin electrophoresis was performed using Capillarys 2 full-automated electrophoresis instrument. Gap polymerase chain reaction and reverse dot blot were used for genetic diagnosis of thalassemia genotyping test. The cut-off value in screening of thalassemia was determined by receiver operating characteristic curve and next to analyze the value of HbA2 and HbF in screening of thalassemia using the decided cut-off value.</p><p><b>RESULTS</b>The areas under the curve (AUC(Roc)) of HbA2 for diagnosis of α-, β- thalassemia were 0.75 and 0.981 respectively, and the AUC(Roc) of HbF for diagnosis of β-thalassemia was 0.787. When HbA2 ≤ 2.55 was taken as the cut-off value of HbA2 for diagnosis of α-thalassemia, the sensitivity, specificity, positive likelihood ratio (LR(+)) and negative likelihood ratio (LR(-)) were 89.5%, 54.8%, 1.98, 0.19 respectively. When HbA2 ≥3.9 was taken as the cut off value of HbA2 for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 96.1%, 99.8% 480.5, 0.04 respectively. When HbF ≥0.75 was taken as the cut off value of HbF for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 83.6%, 61.8% respectively.</p><p><b>CONCLUSION</b>The cut-off value in screening of thalassemia by capillarys 2 full automated electrophoresis instrument is different from that of the traditional method of hemoglobin electrophoresis, such as cellulose acetate membrane electrophoresis and agarose gel electrophoresis. Each laboratory should establish their own respective cut off value.</p>
Asunto(s)
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Valores de Referencia / Hemoglobina Fetal / Hemoglobina A2 / China / Tamizaje Masivo / Estudios Retrospectivos / Sensibilidad y Especificidad / Talasemia beta / Talasemia alfa / Electroforesis Capilar Tipo de estudio: Estudio diagnóstico / Estudio observacional / Estudio pronóstico / Estudio de tamizaje Límite: Femenino / Humanos / Embarazo País/Región como asunto: Asia Idioma: Chino Revista: Journal of Experimental Hematology Año: 2016 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Valores de Referencia / Hemoglobina Fetal / Hemoglobina A2 / China / Tamizaje Masivo / Estudios Retrospectivos / Sensibilidad y Especificidad / Talasemia beta / Talasemia alfa / Electroforesis Capilar Tipo de estudio: Estudio diagnóstico / Estudio observacional / Estudio pronóstico / Estudio de tamizaje Límite: Femenino / Humanos / Embarazo País/Región como asunto: Asia Idioma: Chino Revista: Journal of Experimental Hematology Año: 2016 Tipo del documento: Artículo