Aortic Root Replacement with a Valve Sparing Technique for Quadricuspid Aortic Valve / 日本心臓血管外科学会雑誌
Japanese Journal of Cardiovascular Surgery
;
: 412-415, 2013.
Artículo
en Japonés
| WPRIM
| ID: wpr-374611
ABSTRACT
A 67-year-old man with ascending aortic aneurysm was referred to our hospital. Transthoracic echocardiography showed severe aortic regurgitation with annuloaortic ectasia and transesophageal echocardiography revealed a quadricuspid aortic valve. This patient underwent aortic root replacement with a valve sparing technique. Under deep hypothermic circulatory arrest with retrograde cerebral perfusion, replacement of the ascending aorta was successfully performed. The postoperative course was uneventful. This patient is doing well 6 months after surgery without recurrence of aortic regurgitation.