ABSTRACT
Objective To investigate the value of LigaSure vessel sealing system for surgery in gastroenteric cancer. Methods From January to September 2009,44 cases of gastroenteric cancer were operated by using LigaSure vessel sealing system,including 13 cases of gastric cancer, 14 cases of colon cancer, 17 cases of rectum cancer. Laparoscopy was employed in 10 cases. Results All the cases were performed successfully. The operation time was 130-250 min, the blood loss was 50-250 ml, and the number of lymph nodes resected was 4-20. None of the cases had serious complications. Conclusion As an optimal hemostatic tool, LigaSure vessel sealing system is safe and feasible for gastroenteric cancer.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Postgraduates of Medicine Año: 2010 Tipo del documento: Artículo