Your browser doesn't support javascript.
loading
CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application / 中华放射学杂志
Chinese Journal of Radiology ; (12): 704-707, 2009.
Artículo en Chino | WPRIM | ID: wpr-394077
ABSTRACT
Objective To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography.Methods Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized

design:

(1) Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg).Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline.The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group.The variance analysis and post hoc test were employed for the statistical analysis.Results Compared with 120 kV group(3.4± 0.7), the image quality of 100 kV group(5.2±1.8)had higher noise(52.9%), but subjective index for the image quality demonstrated no differences(q=0.272 ,P=0.063)in mediastinum window while CTDIvol and ERD decreased for 34.9%[(9.5±0.0) vs (14.6±0.0) mGy]and 36.8%[(3.8±0.6) vs (2.4± 0.4) mSv].The mean CT values on pulmonary artery of 100 kV group[(269.2±54.7) HU]were 13.4% (31.8/237.4) higher than the 120 kV group[(237.4±62.9) HU], but there was no statistical differences eornpared to normal group(q=0.172,P=0.260).Conclusion Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT pulmonary angiography.Personalized contrast agent injection has clinical application value for specific patient group.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Ensayo Clínico Controlado Idioma: Chino Revista: Chinese Journal of Radiology Año: 2009 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Ensayo Clínico Controlado Idioma: Chino Revista: Chinese Journal of Radiology Año: 2009 Tipo del documento: Artículo