Study on correlation between residual urine volume after catheterization and body positions for patients with spinal cord injury using B-ultrasonography / 中国实用护理杂志
Chinese Journal of Practical Nursing
;
(36): 68-69, 2009.
Artículo
en Chino
| WPRIM
| ID: wpr-394380
ABSTRACT
Objective To discuss the correlation between residual urine volume after catheterization and body positions for patients with spinal cord injury using B-ultrasonography. Methods 34 patients with spinal cord injury were randomly selected, the residual urine volume in urinary bladder was detected with bed-side B-ultrasonography under different body positions such as supine position, lateral position and fowler position, the results underwent variance analysis. Results No significant difference was seen in residual urine volume in urinary bladder under different body positions. Conclusions Body positions play no significant influence on residual urine volume in urinary bladder after catheterization.