Estimation of typical value and confidence interval of gamma-radiation dose rate from tank-transported copper ore by means of bootstrap resampling method / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection
;
(12): 96-99, 2009.
Artículo
en Chino
| WPRIM
| ID: wpr-396208
ABSTRACT
Objective To investigate the typical value of gamma-radiation dose rate and its confidence interval in tank-transported copper ore by using bootstrap resampling techniques. Methods Bootstrap resampling method, coupled with kernel density estimation, introduced to acquire the typical value of gamma-radiation dose rate in copper ore. Results The typical value of gamma-radiation dose rate in copper ore was expressed as the central tendency of the means of resampling, and two kinds of confidence interval, empirical percentile and bias-corrected accelerated confidence interval, were provided as standard error. Conclusion It is clearly demonstrated that this method has an advantage to give a robust description in explanation of central tendency and variation range of gamma-radiation dose rate data profiles.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Idioma:
Chino
Revista:
Chinese Journal of Radiological Medicine and Protection
Año:
2009
Tipo del documento:
Artículo
Similares
MEDLINE
...
LILACS
LIS