Sirolimus-Eluting Stents for Very Long Lesions in ST-Elevated Myocardial Infarction / 中国循环杂志
Chinese Circulation Journal
; (12): 166-169, 2009.
Article
en Zh
| WPRIM
| ID: wpr-405051
Biblioteca responsable:
WPRO
ABSTRACT
Objective: To evaluate the safety and efficacy of overlapping Sirolimus-eluting stents (SES) in very long lesions during primary percutaneous coronary intervention (PCI) in patients with ST-elevated myocardial infarction (STEMI).Methods: A total of 297 consecutive patients with STEMI underwent primary PCI from January to December 2007 in our hospital were studied.We identified the patients who had 2 or more SES implanted in single long lesion with a single procedure.6 months angiographic and clinical follow-up was performed.The incidences of restenosis and major adverse cardiac event (MACE) during hospitalization and at the follow-up time were analyzed.Results: We identified 31 patients with 31 long lesions who had been implanted more than 2 stents.A median of 2.1 stents were implanted, the median lesion length was 47.2±10.3mm and a median implanted stents'length was 53.2±10.5 mm.6 months clinical follow up rate was 100% and 6 months angiographic follow-up rate was 74.2%, respectively.The incidence of MACE was 8.7% which including target lesion revascularization (TLR).No cardiac death and no fatal myocardial infarction were found.Conclusion: Implantation of SES for very long target lesions seemed to be safe and effective in patients with ST elevated myocardial infarction.Its long-term safety and effectiveness should be further investigated.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Chinese Circulation Journal
Año:
2009
Tipo del documento:
Article