Your browser doesn't support javascript.
loading
Design and feasibility of a novel self-designed reflecting oximeter / 中国组织工程研究
Article en Zh | WPRIM | ID: wpr-409249
Biblioteca responsable: WPRO
ABSTRACT
BACKGROUND: The blood oxygen saturation is an important physiological parameter of human hfe; it can be affected by multiple factors due to the imbalance of oxygen supply and consumption, and consequently, the normal physical metabolism is affected. The existing manufacturing techniques are complex and are used with higher demands. OBJECTIVE: To investigate the accuracy of the novel reflecting oximeter designed on the basis of reflecting principle in monitoring the variance of blood oxygen saturation with the change of its concentration. DESIGN: To introduce the structure, working principle and design of the reflecting oximeter and make comparative study with adult rabbits as the subjects. SETTING: Cardiopolmonary Bypass Department of Cardiovascular disease hospital of the Chinese Academy of MedicalSciences. MATERIALS: The study was performed at the Departments of Anesthesiology and Cardiopulmonary Bypass of the Cardiovascular Disease Hospital,Chinese Academy of Medical Sciences from August to October in 2001.Ten adult rabbits were selected. METHODS: The oximeter consists of a converter, a driver, a central processing mould and liquid-crystal monitor. It is characterized by the onethree optical cable connected with reflecting probe, postcentral management system and digital displayer. This oxmeter was developed basing on the basis of fixed relationship between blood oxygen saturation and radiant absorbency (or reflecting). In this study,cardiovascular-pulmonary bypass was established on rabbits that were then exposed to oxygen and NO mixture supply of different concentrations,and then the corresponding blood oxygen saturations were determined with the new oximeter and compared with series-wound Baite saturation meter and blood-gas analysis. MAIN OUTCOME MEASURES: The blood oxygen saturation at different concentrations determined with the reflecting oximeter and Baite saturation meter. RESULTS: At the same oxygen concentration, the blood oxygen saturation determined with the new measure was not significantly different from that determined with Baite blood oxygen saturation meter(P>0.05 ). CONCLUSION: The variance of blood oxygen saturation with the change of oxygen concentration can be detected by the reflecting oximeter with the result similar to that by Baite blood oxygen saturation meter.
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Tissue Engineering Research Año: 2005 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Tissue Engineering Research Año: 2005 Tipo del documento: Article