Result of anterior Decompression and Stabilization with KANEDA II Device and SURGICAL TITANIUM MESH in Thoracolumbar Unstble Spine Injuries
Journal of Korean Neurosurgical Society
;
: 1156-1162, 1996.
Artículo
en Coreano
| WPRIM
| ID: wpr-41176
ABSTRACT
The following is a retrospective study on the results of anterior spinal surgery with Kaneda II instrumentation and surgical Titanium MESH after thoracolumbar unstable spinal injuries. From July 1994 to June 1995, we operated on 14 patients at the Chosun University Kwang Yang hospital. Fourteen patients were followed for at least three months. Anterior spinal surgery was performed on the patients who had thoracolumbar unstable spine injuries. The procedure consisted of anterior decompression through corpectomy and stabilization with Kaneda II instrumentation and surgical Titanium MESH which was impacked with resected bone chip. Most of patients had demonstrated showed neurological improvement, relief of pain, immediate stabilization and early return to normal activities. Radiologic evaluation showed the correction of the fracture deformity with satisfactory outcome postoperatively.
Texto completo:
Disponible
Índice:
WPRIM (Pacífico Occidental)
Asunto principal:
Traumatismos Vertebrales
/
Columna Vertebral
/
Anomalías Congénitas
/
Titanio
/
Estudios Retrospectivos
/
Descompresión
Tipo de estudio:
Estudio observacional
Límite:
Humanos
Idioma:
Coreano
Revista:
Journal of Korean Neurosurgical Society
Año:
1996
Tipo del documento:
Artículo