Flow cytometry method for antifungal susceptibility test and its clinical application / 中华临床感染病杂志
Chinese Journal of Clinical Infectious Diseases ; (6): 343-347, 2011.
Artículo en Chino | WPRIM | ID: wpr-417390
ABSTRACT
Objective To develop a rapid detection method of flow cytometry for antifungal susceptibility testing.Methods The experiment conditions of flow cytometry were optimized and the minimum inhibitory concentrations (M1Cs) of 230 strains of Candida spp to flucytosin,fluconazol,itraconazole,amphotericin B were detected.The MIC results obtained by flow cytometry were compared with M27-A2 reference assay.Results The agreement of MIC results between flow cytometry and M27-A2method was 85.0% - 100%.Conclusion Flow cytometry can be used as a rapid and reliable method for antifungal susceptibility testing.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Clinical Infectious Diseases Año: 2011 Tipo del documento: Artículo