Your browser doesn't support javascript.
loading
Establishment and assessment of orthotropic and heterotrophic valve implantation models in goat with minimally invasive methods / 中华胸心血管外科杂志
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 670-673, 2012.
Artículo en Chino | WPRIM | ID: wpr-429389
ABSTRACT
Objective To establish and evaluate 3 kinds of minimally-invasive valve implantation model in vivo.Methods A novel tissue engineered heart valve(TEHV) manufactured by branched polyethylene glycol cross-linked acellular porcine valve and a minimally-invasive valve implantation system according to the design of Corevalve revalving system were adopted.After anesthesia,18 adult male goats were randomly divided into 3 groups the ulrasound-directed orthotropic group (group A,n =6),angiography-directed orthotropic group (group B,n =6) and direct-released heterotopic group (group C,n =6),and all received minimally-invasive valve implantation orthotropically or heterotopically.4 weeks later,the valvular function was evaluated by CTA and/or echocardiography.Results All 3 kinds of caprine model were successfully constructed.The operation success rate of each group was A 66.7%,B 50.0% and C 100.0%,respectively(multiple x2 analysis,group A and B P >0.05; group A and C,group B and C,P <0.05).The operation-time of each group was A (79 ± 18) min,B(61 ±23) min,C (45 ± 15) min(one-way ANOVA,P <0.05).The survival rate at4 weeks was A 100%,B 100% and C 83.3% (multiple x2 analysis,P > 0.05).Echocardiography and CTA proved the short-term function of implanted TEHV was satisfactory.Conclusion All 3 kinds of caprine valve implantation model can be established without cardiopulmonary bypass and blood transfusion.The devices and equipments required in group A is relatively simple,but the procedure cost longer time for it is hard to determine the right position by ultrasound.The application of angiography made the positioning much easier in group B while the procedure had to be performed in specific operation room with angiographic apparatus.Group C did rely on neither special equipments nor complex operation,but the valve leaflets cannot work normally,so this model was only suitable for testing in vivo characteristics such as biocompatiblities.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio pronóstico Idioma: Chino Revista: Chinese Journal of Thoracic and Cardiovascular Surgery Año: 2012 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio pronóstico Idioma: Chino Revista: Chinese Journal of Thoracic and Cardiovascular Surgery Año: 2012 Tipo del documento: Artículo