Your browser doesn't support javascript.
loading
Small Malignant Hepatic Tumor Detection in Gadolinium- and Ferucarbotran-Enhanced Magnetic Resonance Imaging: does Combining Ferucarbotran-Enhanced T2*-Weighted Gradient Echo and T2-Weighted Turbo Spin Echo Images have Additive Efficacy?
Article en En | WPRIM | ID: wpr-43028
Biblioteca responsable: WPRO
ABSTRACT
OBJECTIVE: To determine if a combination of ferucarbotran-enhanced T2*weighted-gradient echo (T2*W-GRE) and T2-weighted turbo spin echo (T2W-TSE) images in gadolinium- and ferucarbotran-enhanced MRI has additive efficacy compared to each image alone for detecting small (< or = 2.0 cm) hepatocellular carcinoma (HCC) lesions in a group of cirrhotic patients and metastases in a group of non-cirrhotic patients. MATERIALS AND METHODS: Two readers retrospectively analyzed gadolinium- and ferucarbotran-enhanced T2*W-GRE, T2W-TSE, and combined T2*W-GRE/T2W-TSE images of 119 patients with 157 HCCs and 32 patients with 98 metastases. The diagnostic accuracy and sensitivity for each image set and the combined set were evaluated using the alternative-free response receiver operating characteristic method. RESULTS: The mean area under the curve value of the combined set (0.966) tended to be better than that for each individual image set (T2W-TSE [0.910], T2*W-GRE [0.892]). Sensitivities in the combined set were higher than those in each individual image set for detecting HCC (mean, 93.0% versus 81.6% and 86.7%, respectively, p < 0.01). Sensitivities in the combined set and the T2W-TSE set were the same for detecting metastases, and both were higher than the sensitivity seen in the T2*W-GRE set (mean, 97.5% versus 85.2 %, p < 0.01). CONCLUSION: Combining ferucarbotran-enhanced T2*W-GRE and T2W-TSE has additive efficacy for detecting HCC in cirrhotic patients, but T2W-TSE is preferred for detecting metastases in non-cirrhotic patients.
Asunto(s)
Palabras clave
Texto completo: 1 Índice: WPRIM Asunto principal: Óxidos / Imagen por Resonancia Magnética / Variaciones Dependientes del Observador / Valor Predictivo de las Pruebas / Sensibilidad y Especificidad / Carcinoma Hepatocelular / Medios de Contraste / Gadolinio DTPA / Hierro / Neoplasias Hepáticas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male Idioma: En Revista: Korean Journal of Radiology Año: 2008 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Asunto principal: Óxidos / Imagen por Resonancia Magnética / Variaciones Dependientes del Observador / Valor Predictivo de las Pruebas / Sensibilidad y Especificidad / Carcinoma Hepatocelular / Medios de Contraste / Gadolinio DTPA / Hierro / Neoplasias Hepáticas Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male Idioma: En Revista: Korean Journal of Radiology Año: 2008 Tipo del documento: Article