The application of absorbable self-enhancing cartilage nails in the treatment of radial head fractures / 中华骨科杂志
Chinese Journal of Orthopaedics ; (12): 50-54, 2013.
Artículo en Chino | WPRIM | ID: wpr-432228
ABSTRACT
Objective To evaluate the clinical effect of absorbable self-enhancing cartilage nails in the treatment of radial head fractures.Methods Data of 22 patients with radial head fractures,who had undergone open reduction and internal fixation with absorbable self-enhancing cartilage nails from January 2008 to December 2011,were retrospectively analyzed.Among them,data of 18 patients were complete,including 10 males and 8 females.According to the Mason classification,there were 14 cases of Mason Ⅱ,3 cases of Mason Ⅲ and 1 case of Mason Ⅳ.Two patients were combined with radial neck fractures,9 with osteochondral fractures of capitellum,and 1 with posterior dislocation of the elbow and olecranon avulsion fracture.The radial head fractures were temporarily fixed with Kirschner wires after open reduction,then absorbable self-enhancing cartilage nails with length from 16 to 24 mm and diameters of 1.5 mm were applied to reach final fixation.The heads of nails were right underneath of cartilages without penetrating bone cortexes on the contralateral side.The radial neck fractures were reduced and fixed with T-plates or anatomical plates after the radial head fractures were fixed with cartilage nails.Four cases of osteochondral fracture of capitellum were fixed with absorbable sutures to external epicondyle of humerus.For other 5 cases of osteochondral fracture of capitellum,the bone fragments were removed due to too small to fix.Results All 18 patients were followed up for 6 to 54 months (average,31.3 months).All fractures achieved bone union,and the healing time ranged from 5 to 12 weeks (average,8.7 weeks).There were no complications,such as internal fixation failure,nonunion,hematoma,sinus formation,osteolytic changes of radial heads and so on.According to the Broberg-Morrey elbow performance score,13 cases were excellent,4 good,and 1 fair,with the total excellent and good rate of 94.44% (17/18).At final follow-up,the elbow range of motion was 90° to 150° (average,123.8°),and the range of forearm rotation was 130° to 180° (average,152.5°).Conclusion Absorbable self-enhancing cartilage nails can be used to treat various kinds of radial head fractures,and the results are satisfactory.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Orthopaedics Año: 2013 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Orthopaedics Año: 2013 Tipo del documento: Artículo