Application evaluation of transvaginal sonography in diagnosis of endometrial polyps / 重庆医学
Chongqing Medicine
;
(36): 191-192, 2014.
Artículo
en Chino
| WPRIM
| ID: wpr-439919
ABSTRACT
Objective To investigate the value of transvaginal ultrasound for the diagnosis of endometrial polyps .Methods The ultrasonographic characteristics in 56 cases of endometrial polyp diagnosed by transvaginal ultrasound were performed the retro-spective analysis and the situation of the hysteroscopic examination in consistent with the pathological examination was analyzed . Results Among 56 cases ,50 cases of endometrial polyps were verified by the pathological examination ,the coincidence rate of transvaginal ultrasound diagnosis was 89 .3% ,in which 6 cases were misdiagnosed with the misdiagnosis rate was 10 .7% . Conclusion The transvaginal ultrasound has the high accuracy rate for diagnosing endometrial polyps .