Determination of Vitamin B2 in Weimeisu Tablets by HPLC-FLD / 中国药师
China Pharmacist
; (12): 1515-1516, 2014.
Article
en Zh
| WPRIM
| ID: wpr-456243
Biblioteca responsable:
WPRO
ABSTRACT
Objective:To establish a method for detecting the content of vitamin B2 in Weimeisu tablets by HPLC-FLD. Methods:A PAK C18(250 mmID × 4. 6 mm,5 μm) column was employed with methanol -0. 02 mol·L-1 ammonium acetate (35∶65) as the mobile phase, the flow rate was 1. 0 ml·min-1, and the injection volume was 10 μl. The detection wavelength λex and λem were 450mn and 522 mn, respectively. Results:Vitamin B2 was linear within the range of 1.0-20 μg·ml-1(r=0.999 9). The average recovery was 99. 20%(RSD=0. 63%, n=6). Conclusion:The method is specific, sensitive and accurate, and can be used to deter-mine vitamin B2 in Weimeisu tablets.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
China Pharmacist
Año:
2014
Tipo del documento:
Article