Your browser doesn't support javascript.
loading
Voltammetric quantification of anti-hepatitis drug Adefovir in biological matrix and pharmaceutical formulation / 药物分析学报
Journal of Pharmaceutical Analysis ; (6): 98-104, 2012.
Artículo en Chino | WPRIM | ID: wpr-471761
ABSTRACT
Electrochemical reduction behavior of Adefovir was studied using Hanging Mercury Drop Electrode (HMDE) in Britton-Robinson (BR) buffer solution.Voltammetric study showed one well-defined reduction peak in the potential range -1.2 to -1.4 V (vs.Ag/AgCl) due to reduction of C=N bond of the imidazole ring.Solid-phase extraction and protein-precipitation techniques were employed for extraction of Adefovir from human plasma.The proposed method allows quantification of Adefovir in human plasma over the concentration range 0.50-5.00 μg/mL with the detection limit 0.17 μg/mL,whereas in pharmaceutical formulation 0.25-2.25 μg/mL with the detection limit 0.08 μg/mL.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Journal of Pharmaceutical Analysis Año: 2012 Tipo del documento: Artículo