Application of peripherally inserted central catheter network platform in patients information management / 中华临床营养杂志
Chinese Journal of Clinical Nutrition
; (6): 240-243, 2015.
Article
en Zh
| WPRIM
| ID: wpr-480282
Biblioteca responsable:
WPRO
ABSTRACT
Objective To observe the effect of the application of peripherally inserted central catheter (PICC) network platform in the information management of the patients with PICC.Methods Altogether 17 254 outpatients receiving PICC maintenance in Peking Union Medical College Hospital from April 2012 to April 2013 were enrolled as the control group,including 7 227 males and 10 027 females,with the median age of 58 years (12-85 years).A total of 20 384 outpatients from April 2013 to April 2014 with PICC were selected as the observation group,including 8 188 males and 12 196 females,~th the median age of 59 years (13-86 years).Those patients all received PICC maintenance in outpatient clinic during the intermission of therapy after PICC insertion.The time of data entry,the integrity of the data,description accuracy about complications,and normalization of wording were compared between the two groups.Results The average time of data entry in the control group was (46 ± 6) seconds,significantly longer than that in the observation group [(12 ± 5) seconds,t =562.660,P < 0.05].In terms of the integrity of the data,there were 11 732 cases of complete data,3 623 cases of less complete data,and 1 899 cases of incomplete data in the control group;while the numbers of cases of complete data,less complete data,and incomplete data in the observation group were 19 568,725,and 91,respectively,showing significant difference compared with the control group (x2 =5 312.000,P < 0.05).In the description accuracy about complications,the control group had 11 840 accurately described cases and 5 414 inaccurately described cases,while the observation group had 18 427 accurately described cases and 1 957 inaccurately described cases (x2 =2 814.000,P < 0.05).The wording was standard in 15 280 cases but not standard in 1 974 cases in the control group,and standard in 19 659 cases and not standard in 725 cases in the observation group,with significant inter-group difference (x2 =872.600,P <0.05).Conclusion Simple and convenient data summary could help quality control and quality analysis,preferably guarantee the safety of catheter insertion and reduce the incidence of complications.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Clinical Nutrition
Año:
2015
Tipo del documento:
Article