Your browser doesn't support javascript.
loading
Digital design of standard parts database for distal femoral fractures treated with plating via three-dimensional printing / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 1895-1903, 2016.
Artículo en Chino | WPRIM | ID: wpr-485704
ABSTRACT

BACKGROUND:

On CT reconstruction of three-dimensional (3D) model, fracture virtual reduction and internal fixation cannot be achieved, and reasonable operation scheme cannot be formulated. Digital design can fuly meet the needs of clinical orthopedics physicians. Standard parts database can provide the possibility to choose the ideal internal fixation. 3D printing makes the reasonable operation scheme accurate in clinical implementation.

OBJECTIVE:

To discuss the feasibility, accuracy and minimal invasion of internal fixation in treatment of the distal femoral fracture with digital design of standard parts database by 3D printing.

METHODS:

(1) Nine adult lower extremity specimens were selected to take continuously thin-layer CT scanning. After Dicom images were imported into the mimics software, the model was established. According to the AO classification, they were classified into A1-3, B1-3 and C1-3 types of distal femoral fracture by virtual design. Internal fixation with plate and screw formed standard parts database virtualy. It was printed out the pilot hole of the navigation module design by three-dimensional printing forming technique. Plate and screw were inserted assisted by the module. X-ray and CT scan were taken postoperatively to access the position. (2) 30 patients with distal femoral fracture were subjected to above fixation. The operation time, intraoperative blood loss and postoperative drainage were recorded. Imaging and curative effects were evaluated during folow-up. RESULTS AND

CONCLUSION:

(1) Nine samples underwent X-ray and CT scan. 3D reconstruction results revealed plate position, screw entry point, nail direction, length and diameter were consistent with presetting data in Mimics software. The navigation models were designed to fit the lateral bony structure of distal femur. There were good fitting degree, good card position and good stability when the navigation was applied. It could guide plant and screw implantation. (2) In 30 cases, the operation time was (104.63±26.12) minutes, intraoperative blood loss was (121.74±11.49) mL, and postoperative drainage volume was (30.29±6.38) mL. Al patients were folowed up. According to Schagzker criterion, the efficiency of 22 cases was excelent, 6 cases good and 2 cases average, and the excelent and good rate was 93%. The parameters of length, diameter, orientation and angle were consistent with that preoperatively. (3) Internal fixation formed by standard parts database assisted by 3D printing navigation model has advantages of high accuracy, short process, lessened blood loss, high safety, less complications, and precise fixation. Digital design of standard parts database via3D printing navigation module is expected to achieve implant navigation and application.
Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio pronóstico Idioma: Chino Revista: Chinese Journal of Tissue Engineering Research Año: 2016 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio pronóstico Idioma: Chino Revista: Chinese Journal of Tissue Engineering Research Año: 2016 Tipo del documento: Artículo