Your browser doesn't support javascript.
loading
Monte Carlo method for proton and heavy ion treatment room shielding calculation / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 634-638, 2016.
Artículo en Chino | WPRIM | ID: wpr-496871
ABSTRACT
Objective To use Monte Carlo method to build a shielding calculation model for the proton and heavy ion treatment room,and to provide a reliable calculation method for shielding design.Methods A Monte Carlo-based FLUKA code was adopted to build the shielding calculation model for the proton and heavy ion treatment room,and to simulate the radiation field distribution in the proton and heavy ion treatment room.The calculation model was verified through the radiation detection around the proton and heavy ions treatment room.Results The FLUKA code-based simulation results were consistent with the radiation detection.Conclusions The shielding calculation model based on FLUKA code can simulate the radiation field from proton and heavy ions.Among the secondary particles,secondary neutrons are the dominant component and the main concern of accelerator shielding design.In shielding calculation,the emphasis should be put on both beam intensity and energy.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Evaluación Económica en Salud Idioma: Chino Revista: Chinese Journal of Radiological Medicine and Protection Año: 2016 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Evaluación Económica en Salud Idioma: Chino Revista: Chinese Journal of Radiological Medicine and Protection Año: 2016 Tipo del documento: Artículo