Your browser doesn't support javascript.
loading
Determination of content and encapsulation efficiency of leuprolideacetate microspheres / 中国生化药物杂志
Article en Zh | WPRIM | ID: wpr-510205
Biblioteca responsable: WPRO
ABSTRACT
Objective To establish a determination method for leuprolide acetate microspheres. Methods HPLC was performed on Inertsil ODS-SP (150×4.6 mm×5μm) with mobile phase consist of 0.1 mol/L of Ammonium Dihydrogen Phosphate(adjust its pH to 7.00±0.05 with Ammonium Hydroxide) and Acetonitrile in ratio of 3:1(V/V),and the flow rate was 1.0 mL/min.The wavelength was 220 nm and column temperature was 30℃. The injection volume was 20 μL. Results The linear range of leuprolide acetate was 20.0-160.0μg/mL (r=0.9999) with an average recovery of 99.80%,RSD=0.63%(n=9). Conclusion The method of HPLC was accurate,reliable and specific, which could be used to determinate the assay of leuprolide acetate microspheres and for quality control of microspheres.
Palabras clave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Biochemical Pharmaceutics Año: 2017 Tipo del documento: Article