Your browser doesn't support javascript.
loading
Comparison of Six-Month Outcomes in Eyes with Two Hydrophilic Aspheric Intraocular Lenses after Cataract Surgery
Journal of the Korean Ophthalmological Society ; : 767-774, 2012.
Artículo en Coreano | WPRIM | ID: wpr-51044
ABSTRACT

PURPOSE:

To compare the six-month clinical outcomes of Tek-Lens II model 872 (Tekia, Inc.) and Akreos MI-60 (Bausch & Lomb, Inc.) hydrophilic aspheric intraocular lenses (IOLs) implanted in-the-bag.

METHODS:

After phacoemulsification was performed by a single surgeon (JY Kim), two different hydrophilic aspheric IOLs were implanted the Tek-Lens II IOL in 57 eyes and the MI60 IOL in 49 eyes. The best corrected visual acuity (BCVA), refractive error (RE), total high-order aberration (HOA), anterior chamber depth (ACD), and contrast sensitivity (CS) were measured preoperatively and one, three, and six months postoperatively. All parameters were analyzed using the independent t-test to compare the two IOL groups.

RESULTS:

There was no significant difference in the BCVA, RE, or HOA between the two groups at any of the follow-up visits. Three months postoperatively, the ACD of the TEK-Lens II group as measured by corneal topography was significantly shallower than that of the MI60 group (3.67 +/- 0.52 mm vs. 4.10 +/- 0.40 mm; p = 0.008), and most of the photopic CS in the Tek-Lens II group was significantly higher than that in the MI60 group (all p < 0.05).

CONCLUSIONS:

The Tek-Lens II IOL showed comparable clinical outcomes with a proven hydrophilic aspheric IOL for the postoperative six months.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Errores de Refracción / Catarata / Sensibilidad de Contraste / Agudeza Visual / Estudios de Seguimiento / Facoemulsificación / Topografía de la Córnea / Ojo / Lentes Intraoculares / Compuestos de Anilina Tipo de estudio: Estudio observacional / Estudio pronóstico Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Año: 2012 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Errores de Refracción / Catarata / Sensibilidad de Contraste / Agudeza Visual / Estudios de Seguimiento / Facoemulsificación / Topografía de la Córnea / Ojo / Lentes Intraoculares / Compuestos de Anilina Tipo de estudio: Estudio observacional / Estudio pronóstico Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Año: 2012 Tipo del documento: Artículo