ABSTRACT
Objective To investigate the effect of Site-Rite 5 vascular ultrasound on puncturing of grade Ⅱ and Ⅲ veins.Methods Purposive sampling was used and 59 patients with grade Ⅱ and iⅢ veins to receive peripheral intravenous catheteration (PIV) were divided into observation group and control group according to the different wards30 patients in the observation group and 29 in the control group.The control group received indwelling PIV by routine method and in the observation group,the patients' veins were assessed by Site-Rite 5 ultrasound-guided instrument and marked,followed by puncturing with PIV.The two groups were compared in terms of one-time success rate and incidence of complications.Results The one-time success rate of the observation group was significantly higher than that of the control group.There was no significant difference in the incidence of complications between the two groups (P >0.05).Conclusions By the Site-Rite 5 ultrasound-guided instrument,the invisible veins become visible.It is beneficial to improve the success rate of puncturing.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Modern Clinical Nursing Año: 2016 Tipo del documento: Artículo