Your browser doesn't support javascript.
loading
Reproducibility of VERION Digital Guidance System and its comparability with iTrace, Lenstar LS900 and manual keratometer in measuring keratometry and astigmatism / 眼科新进展
Recent Advances in Ophthalmology ; (6): 267-270, 2017.
Artículo en Chino | WPRIM | ID: wpr-511131
ABSTRACT
Objective To analyze the reproducibility of keratometry and astigmatism measured by the VERION Digital Guidance System and the comparability of VERION with iTrace,Lenstar LS900 and manual keratometer.Methods The keratometry of 62 cataract patients were measured using four different devices.The steep keratometry (Ks),flat keratometry (Kf),astigmatic magnitude,astigmatic axis,cylinder at 0-degree meridian (vector component,J0) and cylinder at 45-degree meridian (vector component,J45) from each machine were recorded and analyzed.The three repeated measurements and the results of VERION system with other three devices were compared to analyze the reproducibility and comparability of VERION system.Results ReproducibilityIntraclass correlation coefficients and Cronbach's alpha values were higher than 0.9 for Ks,Kf,astigmatic magnitude,astigmatic axis,J0 and J45 measured by the VERION system (all P < 0.001).ComparabilityThe results of Ks and magnitude of astigmatism of VERION were larger than the iTrace (all P < 0.05) in the paired-samples t test.There was no statistical difference for the rest of parameters (all P > 0.05).The Bland-Altman graphs revealed the 95% limits of agreement (LOA) of J0,J45 and the astigmatic axis between VERION and iTrace were (-0.31-0.35) D,(-0.25-0.31) D and-13.5 °-12.3 °,respectively;There was no statistical differences for all parameters except for J45 in the paired-samples t test between the VERION and Lenstar LS900 (all P > 0.05).The Bland-Altman graphs revealed the 95% LOA of J0,J45 and the astigmatic axis were (-0.25-0.31)D,(-0.27-0.36) D and-13.5°-11.0°,respectively;There were statistical differences for the results of Kf and magnitude of astigmatism between the VERION and manual keratometer (all P < 0.05).The Bland-Altman graphs revealed the 95% LOA of J0,J45 and the astigmatic axis between VERION and manual keratometer were (-0.38-0.35) D,(-0.41-0.42) D,-12.6°-16.4°,respectively.Conclusion The VERION system is a reliable system for the measurement of keratometry and astigmatism.The keratometry and astigmatic magnitude of the VERION system have a good agreement with the iTrace,Lenstar LS900 and manual keratometer.However,the astigmatic axis measurements are significantly different among the four devices.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Guía de Práctica Clínica Idioma: Chino Revista: Recent Advances in Ophthalmology Año: 2017 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Guía de Práctica Clínica Idioma: Chino Revista: Recent Advances in Ophthalmology Año: 2017 Tipo del documento: Artículo