The Effect of Simethicone as a Bowel Preparative: Is a Higher Dosage More Helpful? / 대한소화기내시경학회지
Korean Journal of Gastrointestinal Endoscopy ; : 251-255, 2007.
Artículo en Coreano | WPRIM | ID: wpr-51600
ABSTRACT
BACKGROUND/

AIMS:

Simethicone has been effectively used as a preprocedure drink during colonoscopy because it causes bubbles in the lumen to coalesce. We tried to confirm whether simethicone could effectively lessen the bubble formation and shorten the procedure time. In addition, we tried to determine the proper dose of this medication.

METHODS:

Patients were randomized to receive 0 mg as a control group (group I), 200 mg of simethicone at 7 PM in the evening before the procedure (group II), or 200 mg at 7 PM in the evening and 200 mg at 7 AM in the next morning (group III). The bubbles were scored as follows 0, none or small amounts of bubbles that don't require any jet of water; 1, moderate amounts of bubbles that require two or three jets of water due to the focal distribution; And 2, large amounts of bubbles that require repeated jets (> or = 4) of water due to the extensive distribution.

RESULTS:

101 patients were included in this study. The number of patients in groups I, II and III were 38, 35 and 28, respectively. The procedure time was statistically similar among the three groups. Severe bubbles (score 2) were significantly more likely to occur in group I than in groups II and III (p=0.014). On the other hand, the presence of significant bubbles (> or = 1) was not different between groups II and III.

CONCLUSIONS:

Simethicone significantly diminished the presence of bubbles. We recommend using 200 mg of simethicone in the evening before the colonoscopy.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Simeticona / Agua / Colonoscopía / Mano Tipo de estudio: Ensayo Clínico Controlado Límite: Humanos Idioma: Coreano Revista: Korean Journal of Gastrointestinal Endoscopy Año: 2007 Tipo del documento: Artículo