Your browser doesn't support javascript.
loading
Effects of fentanyl on the MAC of sevoflurane / 中华麻醉学杂志
Chinese Journal of Anesthesiology ; (12)1994.
Artículo en Chino | WPRIM | ID: wpr-516651
ABSTRACT
To study the effects of fentanyl on the MAC of sevoflurane.

Method:

One hundred and sixteen patients were given continuous infusion of fentanyl with CACI-pump (computer-assisted continuous infusion)to maintain different target plasma concentrations (Ct), meanwhile inhaled sevoflurane. All patients were randomly divided into seven groups receiving sevoflurane in oxygen with fentanyl target plasma concentration of 0?g/L (n=16), 0.5?g/L(n=20), 1?g/L(n=18), 2?g/L(n=16), 3?g/L(n=18), 4?g/L(n= 14) or 6?g/L(n= 14). Plasma concentraion of fentanyl was measured with radioimmunoassay. MAC determination, in response to the stimulus of skin incision, was made using the "up-down" method and logistic regression.

Result:

The MAC of sevoflurane from group 1 to group 7 were 1.94%, 1.89%, 1.55%, 1.29%, 1.09%, 0.86% and 0.35% respectively.

Conclusion:

We verify the MAC of sevoflurane, which is reduced by increasing plasma fentanyl concentration.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Anesthesiology Año: 1994 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Idioma: Chino Revista: Chinese Journal of Anesthesiology Año: 1994 Tipo del documento: Artículo