Your browser doesn't support javascript.
loading
Detection of Aconitine and Mesaconitine and Hypaconitine in blood by LC/MS/MS / 中国法医学杂志
Chinese Journal of Forensic Medicine ; (6)2002.
Artículo en Chino | WPRIM | ID: wpr-523542
ABSTRACT
Objective To establish a method used for determination of Aconitine and Hypaconitine and Mesaconitine in blood by LC/MS/MS.Methods Extraction of blood sample was conducted by use of 1% thirdchloroactic acid and acetonitrile liquid,and the electrospray fog ionic source,and positive ion MRM scan were employed.Result The linearity correlation coefficients(r)was≥0.992 2.The limit of quantification (LOQ S/N=5) was 2.0 ng/ml for Aconitine,0.5 ng/ml for Hypaconitine,and 0.5 ng/ml for Mesaconitine.The recovery of appended contrast in blank blood sample ranged from 91.25% to 103.1% with coefficient of variation (CV,n=6) less than 10.93%.Conclusion The method of LC/MS/MS is sensitive and reliable,and the sample handling is quick and simple,which was suitable for determination of the Aconitine and Hypaconitine and Mesaconitine in blood sample.

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Tipo de estudio: Estudio diagnóstico Idioma: Chino Revista: Chinese Journal of Forensic Medicine Año: 2002 Tipo del documento: Artículo