Your browser doesn't support javascript.
loading
Effects of Varying Concentrations of Enflurane on Respiratory System Mechanics in Cats / 대한마취과학회지
Korean Journal of Anesthesiology ; : 393-398, 1997.
Artículo en Coreano | WPRIM | ID: wpr-53605
ABSTRACT

BACKGROUND:

Flow interruption technique has been used to measure respiratory system mechanics, and its prominent advantage is to partitionate the respiratory system resistance into airway and tissue component. In this study, we investigated the effects of varing concentrations of enflurane on respiratory system mechanics using flow interruption technique.

METHODS:

Six cats, weighing 3.0~3.6 kg were used. Pentobarbital sodium was injected intraperitonially and endotracheal intubation was followed. Intermittent mandatory ventilation was applied with Siemens Servo 900C ventilator. The inspiratory flow rate, tidal volume, and respiratory rate were fixed, and normocarbia (PaCO2; 30~35 mmHg) was maintained throughout the experiment. The changes in the pressure and volume were recorded with Bicore CP100 pulmonary monitor at control, 0.5, 1, 1.5, and 2 MAC of enflurane. The data were transfered to a PC and analyzed by Anadat processing software. Respiratory system, airway and tissue viscoelastic resistances, and dynamic and static compliances were calculated.

RESULTS:

Respiratory system resistances decreased up to 1 MAC of enflurane compared to the control value (p<0.05), but there were no significant differences in the values of resistance among 1, 1.5, 2 MAC of enflurane. There were no significant differences in tissue viscoelastic resistances, and dynamic and static compliances with varying concentrations of enflurane.

CONCLUSIONS:

Enflurane significantly reduces the respiratory system resistance mainly by decreasing airway resistance. Tissue viscoelastic resistance and respiratory system compliances are not influenced by changes in concentration of enflurane.
Asunto(s)

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Pentobarbital / Sistema Respiratorio / Ventilación / Ventiladores Mecánicos / Volumen de Ventilación Pulmonar / Resistencia de las Vías Respiratorias / Mecánica / Enflurano / Frecuencia Respiratoria / Intubación Intratraqueal Límite: Animales Idioma: Coreano Revista: Korean Journal of Anesthesiology Año: 1997 Tipo del documento: Artículo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponible Índice: WPRIM (Pacífico Occidental) Asunto principal: Pentobarbital / Sistema Respiratorio / Ventilación / Ventiladores Mecánicos / Volumen de Ventilación Pulmonar / Resistencia de las Vías Respiratorias / Mecánica / Enflurano / Frecuencia Respiratoria / Intubación Intratraqueal Límite: Animales Idioma: Coreano Revista: Korean Journal of Anesthesiology Año: 1997 Tipo del documento: Artículo